OFFICE HOURS

Monday - Friday
08.00-17.00 CET

SALES SUPPORT

[email protected]
+46 40 15 58 59

G-Series

Refrigerant Gas Detectors

G-Series gas detectors are field-proven over many years, offering simply reliable gas detection for commercial and

industrial refrigerant applications.

There are a number of variants in the G-Series platform to meet application-specific needs, all sharing a common set of features.

These include:

• Operating status displayed via LEDs

• 3 x adjustable alarm levels

• 3 x alarm relay outputs

• Adjustable alarm delay

• Configurable alarm behaviour, auto-reset or latching

• Failsafe operation

• -40°C - + 50°C operating range suitable for all refrigeration environments

• Test terminal for service tools

• Annual maintenance using DT300 service tool

• Power supply options inc. 12-24V AC/DC & 230V AC

G-Series refrigerant gas detectors can be delivered in several versions depending on the application and gas used.

The following options are available:

Model Types

GSH
CO₂ detector using infrared sensor
IP67 enclosure

GSMB
CO₂ detector using infrared sensor
Modbus RTU digital communications
IP67 enclosure

GSLS
CO₂ detector using infrared sensor
High-intensity LED & built-in buzzer (with mute function) for alarm indication
Terminal for connection of a manual remote alarm activation
IP67 enclosure


GD
HFC / HFO / NH3 / R290 / flammable gas / VOC detection using semiconductor sensor
IP21 enclosure

 

 

 


GS
HFC / HFO / NH₃ / R290 / flammable gas / VOC detection using semiconductor sensor
IP54 enclosure

 

 

 


GSR
HFC / HFO / NH₃ / R290 / flammable gas detection using semiconductor sensor
IP54 enclosure
Remote sensor, 5m cable

 

 


GK
HFC / HFO / NH₃ / VOC detection using semiconductor sensor
IP54 enclosure
Remote sensor, 1.5m cable
Ventilation ducts installation
(plastic tube with the sensor mounted with a rubber sleeve directly in the channel)

 


GR
HFC / HFO / NH₃ detector using semiconductor sensor
IP54 enclosure
Remote sensor, 1.5m cable
Vent lines from pressure relief valve installation
Pipe fitting in brass ½ ” Flare

 


GXR
HFC / HFO / NH₃ / R290 / flammable gas detection using semiconductor sensor
IP56 enclosure
ATEX approved remote sensor, 5m cable
Flameproof sensor enclosure (EX d), can be installed in ATEX Zone1
Controller must be installed outside the ATEX area.

 


 

TECHNICAL DATA

GD/GS/GSR/GR/GK:

Housing GS,GSR,GR,GK:Polycarbonate, (PC) IP54 
Housing GD:  Polycarbonate, (PC) IP21 
Power supply: GD/GS/GSR/GR/GK-24: 12-24V AC/DC GD/GS/GSR/GR/GK-230: 230V AC, 50/60 Hz 
Power consumptionMax 2W 
Indications:  Power/Active and alarm indication on three levels. 
Outputs relay:  Potential free contacts (230V, max 5A) . 
Ambient temp: "-40 °C - + 50 °C (Automatic temperature compensation)"
Humidity: 0-95% RH (non-condensing) 
Glands: 4 of M16 membrane glands 
Screw terminals: < 1,5 mm2, fuse < 10A 
Accuracy: ± 5% of the measurement range 
Sensor technology: Semi-conductive 
Response time: 30 s 
Sensors lifetime: 5 years 
Max. Overrange: 130%
Applicable standards: 

EN 378, EN 14624, JRA 4068 

GSH/GSLS

Housing:  Polycarbonate, PC, IP67 
Power supply: 
GSH230 / GSLS230 85…230V AC, 50/60Hz 
GSH24 / GSLS24 12..24V AC/DC 
Power consumption: 3W
Indications:Power/Active and alarm indication on three levels
Outputs relay: Potential free contacts (230V, max 5A) 
Ambient temp:-40 °C..+50 °C 
Humidity: 0-95% Rh (non condensing)
Glands: < 1,5 mm2, fuse < 10A 

GSMB:

Housing: Polycarbonate, PC, IP67
Power supply: 
GSMB230 85..230V AC, 50/60Hz 
GSMB24 12..24V AC/DC
Power consumption: 3W 
Indications:Power/Active and alarm indication on three levels. 
Outputs relay: Potential free contacts (230V, max 5A) 
Ambient temp: 40°C..+50°C 
Humidity: 0..95% RH (non-condensing) 
Glands: 4 of M16 membrane glands 
Screw terminals:< 2,5 mm2 
Data format: Modbus RTU, 19200 baud, 8, N, 1.
Data output: RS-485 compatible ModBus RTU port.  3-pole screw terminal (A / B / GND) (8)

GXR

Housing:  Polycarbonate, PC 
Power supply: 230 V AC, 50/60 Hz (model Gx230-XX)  - 12-24V AC/DC (model Gx24-XX) 
Power consumption: Max 2W 
Indications: Power/Active and alarm indication on three levels. 
Outputs relay: Potential free contacts (230V, max 5A) .
Ambient temp: -40°C to +40°C (Automatic temperature  compensation)
Humidity: 0-95% RH (non-condensing) 
Glands: 4 of M16 membrane glands 
Screw terminals: < 1,5 mm2, fuse < 10A 



Coming soon...

Order Code

Model

Details

PG

GSH
detectors

CO

 

 

 

37-4120

GSH24-CO2-10000

0-10000 ppm, 12..24V AC/DC, max 3 W

A

37-4124

GSH24-CO2-30000

0-30000 ppm, 12..24V AC/DC, max 3W

A

37-4170

GSH230-CO2-10000

0-10000 ppm, 85…230V AC, max 3 W

A

37-4174

GSH230-CO2-30000

0-30000 ppm, 85..230V AC, max 3W

A

GSMB

detectors

CO

 

37-4120-MB

GSMB24-CO2-10000

0-10000 ppm, 12..24V AC/DC, max 3 W

A

37-4124-MB

GSMB24-CO2-30000

0-30000 ppm, 12..24V AC/DC, max 3W

A

37-4170-MB

GSMB230-CO2-10000

0-10000 ppm, 85..230V, Max 3W

A

37-4174-MB

GSMB230-CO2-30000

0-30000 ppm, 85..230V AC, max 3W

A

GSLS

detectors

CO

 

37-4120-LS

GSLS24-CO2-10000

0-10000ppm, 12…24V AC/DC, max 3W

A

37-4124-LS

GSLS24-CO2-30000

0-30000 ppm, 24 V, max 3 W

A

37-4170-LS

GSLS230-CO2-10000

0-10000ppm, 85…230V AC, max 3W

A

37-4174-LS

GSLS230-CO2-30000

0-30000 ppm, 230 V, max 3 W

A

GD

detectors

HFC / HFO / NH / R290 / flammable gas

 

 

 

37-220

GD24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-225

GD230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-252

GD24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-253

GD24-NH3-10000

0-10000 ppm, 12..24V AC/DC, max 2 W

A

37-257

GD230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-258

GD230-NH3-10000

0-10000 ppm, 230V AC/DC, max 2 W

A

37-230

GD24-HC

0-50% LEL, 12..24V AC/DC, Hydrocarbons

A

37-235

GD230-HC

0-50% LEL, 230V AC, Hydrocarbons

A

37-270

GD24-H2

0-50% LEL, 12..24V AC/DC, (Hydrogen)

A

37-275

GD230-H2

0-50% LEL, 230V AC, (Hydrogen)

A

37-280

GD24- Methane

0-50% LEL, 12..24V AC/DC

A

37-285

GD230- Methane

0-50% LEL, 230V AC

A

Order Code

Model

Details

PG

GD

detectors

HFC / HFO / NH / R290 / flammable gas

Continued... 

37-290

GD24- Propane

0-50% LEL, 12..24V AC/DC

A

37-295

GD230- Propane

0-50% LEL, 230V AC

A

37-260

GD24-AQS (VOC)

0-200 ppm, 12..24V AC/DC , max 2 W

A

37-265

GD230-AQS (VOC)

0-200 ppm, 230V AC , max 2 W

A

GS

detectors

HFC / HFO / NH / R290 / flammable gas

Splash Proof

37-420

GS24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-425

GS230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-452

GS24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-453

GS24-NH3-10000

0-10000 ppm, 12..24V AC/DC, max 2 W

A

37-457

GS230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-458

GS230-NH3-10000

0-10000 ppm, 230V AC/DC, max 2 W

A

37-430

GS24-HC

0-50% LEL, 12..24V AC/DC, Hydrocarbons

A

37-435

GS230-HC

0-50% LEL, 230V AC, Hydrocarbons

A

37-470

GS24-H2

0-50% LEL, 12..24V AC/DC, (Hydrogen)

A

37-475

GS230-H2

0-50% LEL, 230V AC, (Hydrogen)

A

37-480

GS24- Methane

0-50% LEL, 12..24V AC/DC

A

37-485

GS230- Methane

0-50% LEL, 230V AC

A

37-490

GS24- Propane

0-50% LEL, 12..24V AC/DC

A

37-495

GS230- Propane

0-50% LEL, 230V AC

A

37-460

GS24-AQS (VOC)

0-200 ppm, 12..24V AC/DC , max 2 W

A

37-465

GS230-AQS (VOC)

0-200 ppm, 230V AC , max 2 W

A

GSR

detectors
with remote sensor

HFC / HFO / NH / R290 / flammable gas

 

 

 

37-920

GSR24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-925

GSR230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-952

GSR24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-953

GSR24-NH3-10000

0-10000 ppm, 12..24V AC/DC, max 2 W

A

Order Code

Model

Details

PG

GSR

detectors
with remote sensor

HFC / HFO / NH / R290 / flammable gas

Continued...

37-957

GSR230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-958

GSR230-NH3-10000

0-10000 ppm, 230V AC/DC, max 2 W

A

37-930

GSR24-HC

0-50% LEL, 12..24V AC/DC, Hydrocarbons

A

37-935

GSR230-HC

0-50% LEL, 230V AC, Hydrocarbons

A

37-980

GSR24-Methane

0-50% LEL, 12..24V AC/DC

A

37-985

GSR230-Methane

0-50% LEL, 230V AC

A

37-990

GSR24-Propane

0-50% LEL, 12..24V AC/DC

A

37-995

GSR230-Propane

0-50% LEL, 230V AC

A

GK

detectors

HFC / HFO / NH

For ventilation ducts

37-820

GK24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-825

GK230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-852

GK24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-857

GK230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-860

GK24-AQS (VOC)

0-200 ppm, 12..24V AC/DC , max 2 W

A

37-865

GK230-AQS (VOC)

0-200 ppm, 230V AC , max 2 W

A

GR

detectors

HFC / HFO / NH /

For vent lines from pressure relief valves

37-620

GR24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-625

GR230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-652

GR24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-657

GR230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

GXR

detectors

HFC / HFO / NH /

With ATEX approved remote sensor

37-720

GXR24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-725

GXR230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-752

GXR24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-757

GXR230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-753

GXR24-NH3-10000

0-10000 ppm, 12…24V AC/DC, max 2W

A

37-758

GXR230-NH3-10000

0-10000 ppm, 230V AC, max 2W

A

37-730

GXR24-Propane

0-50% LEL, 12..24V AC/DC, max 2 W

A

37-735

GXR230-Propane

0-50% LEL, 230V AC, max 2 W

A

Our G-Series refrigerant gas detectors can be delivered with sensors for the following gas types:

CO2
HFC
HFO
NH3
R290

PRODUCT NAME
Short Description
Part no.: XXXXXXX

 

 

 


 

PRODUCT NAME
Short Description
Part no.: XXXXXXX

 

 

 

G-Series gas detectors are field-proven over many years, offering simply reliable gas detection for commercial and

industrial refrigerant applications.

There are a number of variants in the G-Series platform to meet application-specific needs, all sharing a common set of features.

These include:

• Operating status displayed via LEDs

• 3 x adjustable alarm levels

• 3 x alarm relay outputs

• Adjustable alarm delay

• Configurable alarm behaviour, auto-reset or latching

• Failsafe operation

• -40°C - + 50°C operating range suitable for all refrigeration environments

• Test terminal for service tools

• Annual maintenance using DT300 service tool

• Power supply options inc. 12-24V AC/DC & 230V AC

G-Series refrigerant gas detectors can be delivered in several versions depending on the application and gas used.

The following options are available:

Model Types

GSH
CO₂ detector using infrared sensor
IP67 enclosure

GSMB
CO₂ detector using infrared sensor
Modbus RTU digital communications
IP67 enclosure

GSLS
CO₂ detector using infrared sensor
High-intensity LED & built-in buzzer (with mute function) for alarm indication
Terminal for connection of a manual remote alarm activation
IP67 enclosure


GD
HFC / HFO / NH3 / R290 / flammable gas / VOC detection using semiconductor sensor
IP21 enclosure


GS
HFC / HFO / NH₃ / R290 / flammable gas / VOC detection using semiconductor sensor
IP54 enclosure


GSR
HFC / HFO / NH₃ / R290 / flammable gas detection using semiconductor sensor
IP54 enclosure
Remote sensor, 5m cable


GK
HFC / HFO / NH₃ / VOC detection using semiconductor sensor
IP54 enclosure
Remote sensor, 1.5m cable
Ventilation ducts installation
(plastic tube with the sensor mounted with a rubber sleeve directly in the channel)


GR
HFC / HFO / NH₃ detector using semiconductor sensor
IP54 enclosure
Remote sensor, 1.5m cable
Vent lines from pressure relief valve installation
Pipe fitting in brass ½ ” Flare


GXR
HFC / HFO / NH₃ / R290 / flammable gas detection using semiconductor sensor
IP56 enclosure
ATEX approved remote sensor, 5m cable
Flameproof sensor enclosure (EX d), can be installed in ATEX Zone1
Controller must be installed outside the ATEX area.


 

TECHNICAL DATA

GD/GS/GSR/GR/GK:

Housing GS,GSR,GR,GK:Polycarbonate, (PC) IP54 
Housing GD:  Polycarbonate, (PC) IP21 
Power supply: GD/GS/GSR/GR/GK-24: 12-24V AC/DC GD/GS/GSR/GR/GK-230: 230V AC, 50/60 Hz 
Power consumptionMax 2W 
Indications:  Power/Active and alarm indication on three levels. 
Outputs relay:  Potential free contacts (230V, max 5A) . 
Ambient temp: "-40 °C - + 50 °C (Automatic temperature compensation)"
Humidity: 0-95% RH (non-condensing) 
Glands: 4 of M16 membrane glands 
Screw terminals: < 1,5 mm2, fuse < 10A 
Accuracy: ± 5% of the measurement range 
Sensor technology: Semi-conductive 
Response time: 30 s 
Sensors lifetime: 5 years 
Max. Overrange: 130%
Applicable standards: 

EN 378, EN 14624, JRA 4068 

GSH/GSLS

Housing:  Polycarbonate, PC, IP67 
Power supply: 
GSH230 / GSLS230 85…230V AC, 50/60Hz 
GSH24 / GSLS24 12..24V AC/DC 
Power consumption: 3W
Indications:Power/Active and alarm indication on three levels
Outputs relay: Potential free contacts (230V, max 5A) 
Ambient temp:-40 °C..+50 °C 
Humidity: 0-95% Rh (non condensing)
Glands: < 1,5 mm2, fuse < 10A 

GSMB:

Housing: Polycarbonate, PC, IP67
Power supply: 
GSMB230 85..230V AC, 50/60Hz 
GSMB24 12..24V AC/DC
Power consumption: 3W 
Indications:Power/Active and alarm indication on three levels. 
Outputs relay: Potential free contacts (230V, max 5A) 
Ambient temp: 40°C..+50°C 
Humidity: 0..95% RH (non-condensing) 
Glands: 4 of M16 membrane glands 
Screw terminals:< 2,5 mm2 
Data format: Modbus RTU, 19200 baud, 8, N, 1.
Data output: RS-485 compatible ModBus RTU port.  3-pole screw terminal (A / B / GND) (8)

GXR

Housing:  Polycarbonate, PC 
Power supply: 230 V AC, 50/60 Hz (model Gx230-XX)  - 12-24V AC/DC (model Gx24-XX) 
Power consumption: Max 2W 
Indications: Power/Active and alarm indication on three levels. 
Outputs relay: Potential free contacts (230V, max 5A) .
Ambient temp: -40°C to +40°C (Automatic temperature  compensation)
Humidity: 0-95% RH (non-condensing) 
Glands: 4 of M16 membrane glands 
Screw terminals: < 1,5 mm2, fuse < 10A 

Coming soon...

Order Code

Model

Details

PG

GSH
detectors

CO

 

 

 

37-4120

GSH24-CO2-10000

0-10000 ppm, 12..24V AC/DC, max 3 W

A

37-4124

GSH24-CO2-30000

0-30000 ppm, 12..24V AC/DC, max 3W

A

37-4170

GSH230-CO2-10000

0-10000 ppm, 85…230V AC, max 3 W

A

37-4174

GSH230-CO2-30000

0-30000 ppm, 85..230V AC, max 3W

A

GSMB

detectors

CO

 

37-4120-MB

GSMB24-CO2-10000

0-10000 ppm, 12..24V AC/DC, max 3 W

A

37-4124-MB

GSMB24-CO2-30000

0-30000 ppm, 12..24V AC/DC, max 3W

A

37-4170-MB

GSMB230-CO2-10000

0-10000 ppm, 85..230V, Max 3W

A

37-4174-MB

GSMB230-CO2-30000

0-30000 ppm, 85..230V AC, max 3W

A

GSLS

detectors

CO

 

37-4120-LS

GSLS24-CO2-10000

0-10000ppm, 12…24V AC/DC, max 3W

A

37-4124-LS

GSLS24-CO2-30000

0-30000 ppm, 24 V, max 3 W

A

37-4170-LS

GSLS230-CO2-10000

0-10000ppm, 85…230V AC, max 3W

A

37-4174-LS

GSLS230-CO2-30000

0-30000 ppm, 230 V, max 3 W

A

GD

detectors

HFC / HFO / NH / R290 / flammable gas

 

 

 

37-220

GD24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-225

GD230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-252

GD24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-253

GD24-NH3-10000

0-10000 ppm, 12..24V AC/DC, max 2 W

A

37-257

GD230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-258

GD230-NH3-10000

0-10000 ppm, 230V AC/DC, max 2 W

A

37-230

GD24-HC

0-50% LEL, 12..24V AC/DC, Hydrocarbons

A

37-235

GD230-HC

0-50% LEL, 230V AC, Hydrocarbons

A

37-270

GD24-H2

0-50% LEL, 12..24V AC/DC, (Hydrogen)

A

37-275

GD230-H2

0-50% LEL, 230V AC, (Hydrogen)

A

37-280

GD24- Methane

0-50% LEL, 12..24V AC/DC

A

37-285

GD230- Methane

0-50% LEL, 230V AC

A

Order Code

Model

Details

PG

GD

detectors

HFC / HFO / NH / R290 / flammable gas

Continued... 

37-290

GD24- Propane

0-50% LEL, 12..24V AC/DC

A

37-295

GD230- Propane

0-50% LEL, 230V AC

A

37-260

GD24-AQS (VOC)

0-200 ppm, 12..24V AC/DC , max 2 W

A

37-265

GD230-AQS (VOC)

0-200 ppm, 230V AC , max 2 W

A

GS

detectors

HFC / HFO / NH / R290 / flammable gas

Splash Proof

37-420

GS24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-425

GS230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-452

GS24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-453

GS24-NH3-10000

0-10000 ppm, 12..24V AC/DC, max 2 W

A

37-457

GS230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-458

GS230-NH3-10000

0-10000 ppm, 230V AC/DC, max 2 W

A

37-430

GS24-HC

0-50% LEL, 12..24V AC/DC, Hydrocarbons

A

37-435

GS230-HC

0-50% LEL, 230V AC, Hydrocarbons

A

37-470

GS24-H2

0-50% LEL, 12..24V AC/DC, (Hydrogen)

A

37-475

GS230-H2

0-50% LEL, 230V AC, (Hydrogen)

A

37-480

GS24- Methane

0-50% LEL, 12..24V AC/DC

A

37-485

GS230- Methane

0-50% LEL, 230V AC

A

37-490

GS24- Propane

0-50% LEL, 12..24V AC/DC

A

37-495

GS230- Propane

0-50% LEL, 230V AC

A

37-460

GS24-AQS (VOC)

0-200 ppm, 12..24V AC/DC , max 2 W

A

37-465

GS230-AQS (VOC)

0-200 ppm, 230V AC , max 2 W

A

GSR

detectors
with remote sensor

HFC / HFO / NH / R290 / flammable gas

 

 

 

37-920

GSR24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-925

GSR230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-952

GSR24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-953

GSR24-NH3-10000

0-10000 ppm, 12..24V AC/DC, max 2 W

A

Order Code

Model

Details

PG

GSR

detectors
with remote sensor

HFC / HFO / NH / R290 / flammable gas

Continued...

37-957

GSR230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-958

GSR230-NH3-10000

0-10000 ppm, 230V AC/DC, max 2 W

A

37-930

GSR24-HC

0-50% LEL, 12..24V AC/DC, Hydrocarbons

A

37-935

GSR230-HC

0-50% LEL, 230V AC, Hydrocarbons

A

37-980

GSR24-Methane

0-50% LEL, 12..24V AC/DC

A

37-985

GSR230-Methane

0-50% LEL, 230V AC

A

37-990

GSR24-Propane

0-50% LEL, 12..24V AC/DC

A

37-995

GSR230-Propane

0-50% LEL, 230V AC

A

GK

detectors

HFC / HFO / NH

For ventilation ducts

37-820

GK24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-825

GK230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-852

GK24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-857

GK230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-860

GK24-AQS (VOC)

0-200 ppm, 12..24V AC/DC , max 2 W

A

37-865

GK230-AQS (VOC)

0-200 ppm, 230V AC , max 2 W

A

GR

detectors

HFC / HFO / NH /

For vent lines from pressure relief valves

37-620

GR24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-625

GR230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-652

GR24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-657

GR230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

GXR

detectors

HFC / HFO / NH /

With ATEX approved remote sensor

37-720

GXR24-HFC-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-725

GXR230-HFC-4000

0-4000 ppm, 230V AC, max 2 W

A

37-752

GXR24-NH3-4000

0-4000 ppm, 12..24V AC/DC, max 2 W

A

37-757

GXR230-NH3-4000

0-4000 ppm, 230V AC, max 2 W

A

37-753

GXR24-NH3-10000

0-10000 ppm, 12…24V AC/DC, max 2W

A

37-758

GXR230-NH3-10000

0-10000 ppm, 230V AC, max 2W

A

37-730

GXR24-Propane

0-50% LEL, 12..24V AC/DC, max 2 W

A

37-735

GXR230-Propane

0-50% LEL, 230V AC, max 2 W

A

Our G-Series refrigerant gas detectors can be delivered with sensors for the following gas types:

CO2
HFC
HFO
NH3
R290

PRODUCT NAME
Short Description
Part no.: XXXXXXX

 

 

 


 

PRODUCT NAME
Short Description
Part no.: XXXXXXX